SE95004 Rev. 9August 2012Cleveland™Maintenance Procedures& Parts Lists Electric Table Top KettlesFor units built after April 20101333 East 179th S
CALIBRATING PROCEDURE1. Kettle must be empty when this procedure is executed.2. Insure the unit has a vacuum before you begincalibrating procedures. I
3. Pull Pressure Relief Valve (A) open to insure vessel isnot pressurized.4. Remove Pressure Relief Valve (A).5.Replace Pressure Relief Valve (A) with
VACUUM LEAKSIf unit will not hold a vacuum the most likely cause is aleak at one of the fittings.Often, the easiest way to eliminate a leak is reseal
SERVICE PARTSWARRANTYOur Company supports a worldwide network of Maintenance and Repair Centers. Contact your nearestMaintenance and Re
KETTLE BOTTOM & SIDEITEM NO. PART NO. DESCRIPTION QTY.1. KE50556-1 Probe, Low Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ITEM NO. PART NO. DESCRIPTION QTY.Single/Twin1. SE00114 Potentiometer with ON/OFF Switch, c/w Item #2 . . . . . . . . . . . . . . . . . . . . . . . .
TRUNNIONSHOWNFOR CLARITYF6 & 12 GALLON20 GALLON4768910113334569814301529131235A2APPLY RTV SEALANT3219B19A3135B32128TILTING GEARBOX ASSEMBLY(6, 12
380-400V (HIGH VOLTAGE)3 KE52548 ELECTRONIC BOX BRACKET (NOT SHOWN) 1380-600V (HIGH VOLTAGE)KE00225-2 G(HIGH VOLTAGE)ELECTRICAL PANEL ASSEMBLIE
WIRING DIAGRAM3 Gallon Kettles200-240vSingle Phase Only380-480vSingle Phase Only
WIRING DIAGRAM6-20 Gallon200-240v380-600v
STATEMENT OF RESPONSIBILITIES /DÉCLARATION DES RESPONSABILITÉS / DECLARACIÓN DE RESPONSABILIDADESThis document is for use by experiencedand trained Qu
PPoossssiibbllee CCaauusseess1. No incoming power.2. Kettle is tilted.3. Low water condition.4. Defective ON/OFF switch.5. Defective 12 VDC relay. 6.
6. Is there 120 VAC present across the coils of the contactors?Yes - Replace defective contactor/s.No - Go to step #7.7. Remove wire from low water l
PPoossssiibbllee CCaauusseess1. Defective thermistor2. Defective potentiometer (temperature control).3. Defective 12 VDC relay.4. Defective control b
B/ MECHANICAL CHECKS1. Inspect controls, replace damaged seals, switches, LED's etc..2. Remove the console cover and check that the seal is not c
E/ LOW WATER LEVEL PROBE:Probe bypassed byrunning (A) anadditional wireProbe properlyattached✔✘Probe bypassed by(B) grounding theconnecting wire✘(A)(B
✘Plug✘Tube diameter reduced✘Plumbed to drain or water line123✔✔Incorrect Installations1Safety valve has plug threaded into the discharge opening prev
BEARING LUBRICATINGPROCEDURE1. Remove console cover.2. Loosen two Allen screws on locking ring.3. Pull locking ring to center of trunnion.5. Clean new